Model | R5KLNA | R6KLNA | R8KLNA | R10KLNA | R12KLNA | R16KLNA |
PV Input Parameters | ||||||
Max. PV Input Power(KW) | 7.5 | 9 | 12 | 15 | 18 | 24 |
Max. PV Input Voltage(V) | 500 | |||||
MPPT Voltage Range (V) | 120~500 | |||||
Number of MPPT Trackers | 4 | |||||
Max. Input Current per MPPT (A) | 14/14/14/14 16/16/16/16 20/20/20/20 | |||||
Max. Short-circuit Current per MPPT (A) | 22/22/22/22 25/25/25/25 | |||||
Battery Input Parameters | ||||||
Battery Type | Lithium-ion battery / Lead-acid battery | |||||
Max. Charge / Discharge Power (kW) | 5 | 6 | 8 | 10 | 12 | 16 |
Battery Voltage Range (V) | 40-58 | |||||
Rated Battery Voltage (V) | 48 | |||||
Battery Charging Strategy | Adaptive BMS | |||||
BMS Communication | CAN | |||||
AC Output Parameters (Grid-tied Mode) | ||||||
Rated Output Power (kW) | 5 | 6 | 8 | 10 | 12 | 16 |
Rated Grid Voltage (V) | Split-phase (110~120)/(220~240V), 240V Single-Phase | |||||
Rated Grid Frequency (Hz) | 50 / 60(45 ~ 54.9 / 55 ~ 65) 60 (55 ~ 65) | |||||
THDi | < 3% | |||||
AC Output Parameters (Backup Power Off-grid Mode) | ||||||
Rated Output Power (kW) | 5 | 6 | 8 | 10 | 12 | 13 |
Rated Output Voltage (V) | 120/240 | |||||
Rated Output Frequency (Hz) | 60 | |||||
Protection Functions | ||||||
Supported Protections | PV reverse polarity protection, anti-islanding protection, grounding fault protection, leakage current protection, insulation resistance detection, overload output short-circuit protection, AC overcurrent protection, AC overvoltage protection | |||||
Certifications & Standards | ||||||
Safety | UL1741SA all options, UL1699B, CSA 22.2 | |||||
EMC | FCC part 15 class | |||||
Certifications | IEEE 1547, IEEE 2030.5, Hawaii rule 14H, Rule 21 phase I, II, III | |||||
General Specifications | ||||||
Max. Battery Load Efficiency | ≥97.2% | |||||
Ingress Protection Rating | IP65 / Type 3R | |||||
Operating Temperature Range (℃) | -25 ~ +60 | |||||
Cooling Method | Natural Convection | |||||
Dimensions W×D×H (mm) | 450 x 240 x 820 | |||||
Noise Level (dB) | <48 | |||||
PV Connection Terminal | MC4 | |||||
Communication Interfaces | RS485 / CAN | |||||